Product Details
BLASTSHIELD GSA-TS01-20003
- BLASTSHIELD GSA FIRST: Standard clear blast-resistant glass tested to GSA-TS01-2003 standard
- BLASTSHIELD GSA CLARITY: Ultra-clear blast-resistant glass tested to GSA-TS01-2003 standard
- BLASTSHIELD GSA TONE: Tinted blast-resistant glass tested to GSA-TS01-2003 standard
- BLASTSHIELD GSA SOLAR: Solar-control blast-resistant glass tested to GSA-TS01-2003 standard
- BLASTSHIELD GSA COMBI: Insulated or multi-laminated blast-resistant glass tested to GSA-TS01-2003 standard to satisfy additional requirements - thermal insulation, fire-safety, bullet-resistance and/or blast resistance
- BLASTSHIELD GSA EN: Comprehensive framing systems for windows, doors and shutters for burglar resistant glass
BLASTSHIELD ISO 16933
- BLASTSHIELD ISO FIRST: Standard clear blast-resistant glass tested to ISO 16933 standard
- BLASTSHIELD ISO CLARITY: Ultra-clear blast-resistant glass tested to ISO 16933 standard
- BLASTSHIELD ISO TONE: Tinted blast-resistant glass tested to ISO 16933 standard
- BLASTSHIELD ISO SOLAR: Solar-control blast-resistant glass tested to ISO 16933 standard
- BLASTSHIELD ISO COMBI: Insulated or multi-laminated blast-resistant glass tested to ISO 16933 standard to satisfy additional requirements - thermal insulation, fire-safety, bullet-resistance and/or blast resistance
- BLASTSHIELD ISO EN: Comprehensive framing systems for windows, doors and shutters for burglar resistant glass
GSA-TS01-20003
PERFORMANCE CONDITION | PROTECTION LEVEL | HAZARD LEVEL | DESCRIPTION OF WINDOW GLAZING RESPONSE |
---|---|---|---|
1 | Safe | None | Glazing does Glazing does not break. No visible damage to glazing or frame. |
2 | Very High | None | Glazing cracks but it retained by the frame. Dusting or very small fragments near sill or on floor acceptable. |
3A | High | Very Low | Glazing cracks and fragments enter space and land on floor no further than 3.3 ft from the window. |
3B | High | Low | Glazing cracks and fragments enter space and land on floor no further than 10 ft from the window. |
4 | Medium | Medium | Glazing cracks and fragments enter space and land on floor and impact a vertical witness panel at a distance of no more than 10 ft from the window at a height no greater than 2 ft above the floor |
4 | Low | High | Glazing cracks and window system fails catastrophically. Fragments enter space, impacting a vertical witness panel at a distance of no more than 10 ft from the window at a height no greater than 2 ft above the floor |
ISO 16933
SECURITY LEVEL | SECURITY LEVEL | HAZARD LEVEL | DESCRIPTION |
---|---|---|---|
A | Safe | No Breakage | No glass breakage. No visible damage to the glazing or frame. |
B | Very High | No Risk | Glass breaks but remains completely in the frame. No openings in the glass and no splinters in the room. |
C | High | Minimal Risk | Glass breaks, but remains in the frame. Dirt or very small fragments on the window sill or floor are acceptable. |
D | High | Very Low Risk | Glass breaks and can be found a maximum of 1 m behind its original location. |
E | Medium | Low Risk | Glass breaks and fragments can be found up to 3 m behind the test object. No more than 10 perforations higher than 0.5 m can be found on the rear wall, and none with a depth of more than 12 mm. |
F | Low | High Risk | Glass breaks. More than 10 perforations higher than 0.5 m in the rear wall and with a depth of 12 mm. |
FEATURE | DESCRIPTION |
---|---|
Minimum Size | 250 mm X 350 mm |
Maximum Size | Varies as per the standard and framing requirements |
THINNESTUp to 25% thinner | LIGHTEST15-20% lighter | CLEARESTMinimum 5% clearer |